AEMC Waterproof Power & Energy Logger Model PEL 105
|
Price: From $3,500.00 to $4,650.00
Choose Your Model
Model Options: |
|
|
AEMC Waterproof Power & Energy Logger Model PEL 105
AEMC’s Model PEL 105 is a simple to use, power and energy data logger that monitors both traditional and renewable energy sources. It monitors and records True RMS voltage and current, power, energy, cost and harmonics locally or from anywhere in the world. The PEL 105 is built into a waterproof case with an IP67 rating designed for outdoor use and is ideal for pole mounting and can be powered from a phase being monitored. This product is perfect for electricians, engineers and contractors doing work in the areas of building and system monitoring and upgrades, including compliance to article 220.87 of the NEC, as well as overall energy audits and incoming power monitoring. It is available with an Android™ App to configure, view and capture data wirelessly. Bluetooth and Wi-Fi wireless communication provides the operator with the ability to work from a safe distance away from dangerous voltages and currents without the need to wear PPE gear.
Product Features:
- Built into waterproof case with IP67 rating
- Simple to use, single, dual-split and three phase power and energy logger
- 1000V CAT IV
- Measurement of RMS voltages and currents at 128 times per cycle and stored every second
- Power Measurements: VA, W and var
- Energy Measurements: VAh, Wh (source load) and varh (quadrant indication)
- Updated features in DataView software for configuring real-time communication with a PC and report generation with pre-defined or user defined templates
- USB, LAN, Ethernet and Bluetooth (Class 1 wireless communication, up to 300 ft. away)
- WiFi communication
- Minimal programming required
- Can be configured from front panel, through Dataview control panel or free app
- Satisfies the recommendations of NEC Code 220.87
- Provides all the necessary functions for power and energy data logging for 50Hz, 60Hz, 400Hz and DC distribution systems
- Automatic recognition of the connected current sensors/probes
- Can be powered directly from AC Phase measurement
Applications:
- Measure efficiency, find areas for potential savings
- Track sub-billing occupants for energy costs
- Assign energy costs to departments or operations within a department
- Track peak demand periods and find opportunities for surcharge reductions
- Determine present capacity and circumvent unnecessary electrical expansion costs
- Monitor stray voltages and neutral current
- Verify the reliability and operation of electrical machinery
- Improve response time to solve power related problems
- Track energy availability and reliability of supply
- Reduce field service time at sub-stations
- Baseline studies for system upgrades in high-rise and office buildings
- Remote configurations, monitoring and event loading
Model Description:
Model PEL 105 - Cat. #2137.57 (no sensors): Includes large classic tool bag,5 ft USB cable, five black test leads and alligator clips, power adapter w/ power cord, 12 color-coded ID markers, safety card, 8GB SD-Card installed, USB-SD-Card adapter, 9.6V NiMh battery installed, quick start user guide, and USB stick supplied with DataView® software and user manual.
Model PEL 105 - Cat. #2137.59 (with sensors): Includes large classic tool bag, four 24" AmpFlex® A196-24-BK sensors, 5 ft USB cable, five black test leads and alligator clips, power adapter w/ power cord, 12 color-coded ID markers, safety card, 8GB SD-Card installed, USB-SD-Card adapter, 9.6V NiMh battery installed, quick start user guide, and USB stick supplied with DataView® software and user manual.
Inputs
|
5 Voltage / 4 Current
|
Sample Rate
|
128 per Cycle
|
6.4kHz at 50Hz
|
7.68kHz at 60Hz
|
Specification
|
Range
|
Measurement Range
|
Resolution
|
Accuracy (Typical)
|
Volt
|
Vrms
|
1000V P to N
|
10 to 1000V
|
0.1V
|
±0.2% Rdg +0.2V
|
Vrms
|
1000V E to N
|
10 to 1000V
|
0.1V
|
±0.2% Rdg +0.2V
|
Urms
|
1000V P to P
|
17 to 1000V
|
0.1V
|
±0.2% Rdg + 0.4V
|
Amps @ 50 and 60Hz
|
Amps (1V nominal)
(excluding clamp accuracy
|
Probe dependent
|
0.2%< I < 120% Inom
|
Probe dependent
|
±0.2% Rdg + 0.02% Inom
|
AmpFLEX & MiniFlex
(including sensor accuracy)
|
Range 100A
Range 400A
Range 2kA
Range 10kA
|
200mA to 120A
5 to 440A
50 to 2400A
400A to 12kA
|
1mA
0.1A
0.1A & 1A
1A
|
±1.2% Rdg + 50mA
±1.2% Rdg + 0.2A
±1.2% Rdg + 1A
±1.2% Rdg + 5A
|
Frequency
|
|
42.5 to 69Hz
|
0.01Hz
|
±0.1Hz
|
Power
|
Watts (VA, var) P-Q-S
|
20W to 20GW / 20var to 10Gvar / 20VA to 10GVA
|
4 digits min
|
±0.5% Rdg + 0.005% Pnom
|
Power Factor (Cos Φ/DPF)
|
-1 to 1
|
0.001
|
±0.05
|
Energy
|
kWh (kVAh, kvarh) P-Q-S
|
Up to 4EWh / 4Evarh / 4 EVAh (E = 1018 )
|
±0.5% Rdg
|
Harmonics
|
DC, 1 to 50
|
Volts & Amp %
|
|
0.01 to 655.0%
|
0.01%
|
±1% Rdg from 1 to 25
|
THD
|
|
0.00 to 655.0%
|
0.01%
|
±1% Rdg
|
General Features
|
Case
|
Design Rugged field case
|
Interface
|
Isolated USB, Bluetooth, and Ethernet, Wi-Fi, SD card for direct transfer to PC. Dataview software for real time data, configuration and reporting included
|
Memory
|
8GB SD card (SDHC compliant, FAT32 formatted) 32GB max
|
Display
|
LCD with backlight 4.2 x 3.3” (107 x 84mm)
|
Real-Time Clock
|
Time and date stamp for Trend mode
|
Power
|
Phase to phase or phase to neutral 100 to 1000VAC or external power pack 110V/230V 50/60Hz 15VA; Battery backup when power OFF, 60 minutes typical
|
Dimensions (L x W x H)
|
9.65 x 10.6 x 7.1” (245 x 270 x 180mm)
|
Weight
|
8.9 lbs (4kg)
|
Altitude Operating
|
2000m (6560ft)
|
Operating Temperature
|
32° to 108.5°F; (0° to +42.5°C) from 10 to 85% RH
|
Storage Temperature
|
-4° to 122°F; (-20° to +50°C) from 0 to 75% RH with battery pack
|
Electro-Magnetic-Compatibility (EMC)
|
EN 61326-1 for emission and immunity
|
IP Rating
|
IP 67 per IEC 60529
|
Safety
|
IEC/EN 61010-1 (1000V CAT IV Pol 4)
|
|
|
|