Additel ADT209 and ADT210 Series Loop Calibrator
|
|
Price: From $1,133.00 to $1,492.00
Choose Your Model
| Model/Accuracy: |
|
Options
Test leads for Additel 209 and 210
|
Additel ADT209 and ADT210 Series Loop Calibrator
OVERVIEW
The new Additel 209 and 210 loop calibrator series combine ease of use and functionality, making them the ideal tools to troubleshoot your process loop. The ADT209 has an accuracy of 0.03% of reading whereas the ADT210 holds an accuracy of 0.01% of reading. If you want to source, simulate or simply measure the Additel Loop calibrator series will fit your need. The ADT209 and ADT210 allow for measurement of current, voltage and a switch. You can also simulate or source mA or a process transmitter. With a push of a button, you can switch to zero and span values, auto ramp, and auto step throughout the range. Each loop calibrator has a large, easy to read screen which simultaneously displays the measurement with the % of span.
GENERAL FEATURES
• Accuracy to 0.01% of reading
• Small and rugged handheld design
• Measure, source, or simulate loop current
• Measure DC volts
• Simultaneously mA and % span display
• Switch functionality
• Selectable ramp and step functions
• Easy to read display and user interface
• HART 250Ω resistor in series with 24V loop
APPLICATIONS
The ADT209 and ADT210 allow for measurement of current, voltage and a switch. You can also simulate or source mA or a process transmitter. With a push of a button, you can switch to zero and span values, auto ramp, and auto step throughout the range.
SPECIFICATIONS
|
Electrical Measure Specifications
|
|
|
Range
|
Resolution
|
ADT209 Accuracy
|
ADT210 Accuracy
|
|
Voltage DC
|
0 to 30 V
|
1 mV
|
0.03%RD + 2mV
|
0.01%RD + 2mV
|
|
Current DC
|
0 to 24 mA
|
1 µA
|
0.03%RD + 2µA
|
0.01%RD + 2µA
|
|
Switch test
|
Input resistance more than 500 MΩ
Trigger level: low level <0.3V; high level: >2V
|
[1] 1MΩ input resistance
[2] Loop transmitter current measure: 700Ω maximum
|
Electrical Source Specifications
|
|
|
Range
|
Resolution
|
ADT209 Accuracy
|
ADT210 Accuracy
|
|
Current DC
|
0 to 24 mA
|
1 µA
|
0.03%RD + 2µA
|
0.01%RD + 2µA
|
|
Source mode
|
7000/20 mA Maximum
|
|
Sink mode
|
External loop voltage nominal 24V, maximum 30V, minimum 12V
|
Don't have Reader?
|
|
|