Your cart is empty.



   
 

   

 

Additel AccuMac AM1760 and AM1762 Secondary SPRTs

<< Previous in Temperature Next in Temperature >>

Price: Call for pricing
Manufacturer: ADDITEL *Call for Pricing*

Choose Your Model

Model:
Size:
Connection:

Options

Accessories/Replacements
Additel AccuMac AM1760 and AM1762 Secondary SPRTs

  • Reliable SPRT for Daily Use
  • Rtpw Drift: <4mK after 100hrs at 661°C
  • Short-term Stability : <0.002°C at 0.01°C
  • Temperature Range: -200°C to 670°C
  • Inconel™ Sheath to Withstand Harsh Environments
  • Fully Meets the ITS-90 Criteria for Reference Thermometers 
  • ISO 17025 Accredited Calibration Included 
The AM1760 series Secondary SPRTs provides our customers with reliable secondary standards that can be used daily in their labs. These SPRTs feature an accuracy of <0.006°C at 0.01°C, a short term stability of <0.002°C and a very low drift rate of less than 0.004°C after 100 hours at 661°C. Two different lengths of these SPRTs are available at either12 inches (305 mm) or 20 inches (508 mm).

The sensing element is designed to protect the platinum sensing wire from contamination at high temperatures, giving these SPRTs a high level of stability and repeatability in performance. A uniquely designed support structure and filling material provides excellent balance between the hysteresis effect, mechanical shock and thermal shock performance. 

This high performance probe fully meets the ITS-90 criteria for reference thermometers. Each probe comes standard with an ISO 17025 Accredited Calibration.
.

Optional Accessories:
9070- Smart connector for reference PRT for use with Additel temeprature products
9071- Connector adapter from Additel smart connector to 4-wire with gold plated spades
9072- Connector adapter from Additel smart connector to 4-wire with clamps
Note: Carrying Case Included (Excludes - Bend probes)
General Specifications  
  AM1760 AM1762 AM1760-BEND AM1762-BEND
Temperature Range -200°C to 670°C
Nominal Resistance at 0°C 100 Ω 25 Ω 100 Ω 25 Ω
Temperature Coefficient 0.003925 Ω/Ω/°C
Calibrated Accuracy (k=2) [1][2]
±0.010°C at -196°C
±0.006°C at 0.01°C
±0.015°C at 420°C
±0.025°C at 661°C
Long Term Drift at 0.01°C [3] <0.004°C at TPW after 100 hours at 661°C
Short Term Stability <0.002°C
Thermal Shock <0.002°C after 10 thermal cycles from minimum to maximum temperatures
Self-heating 0.0015°C at 0.5 mA current 0.0015°C at 1 mA 0.0015°C at 0.5 mA 0.0015°C at 1 mA
Response Time [4] 9 seconds
Measurement Current 0.5 mA 1 mA 0.5 mA 1 mA
Sensor Length 1.65 in (42 mm)
Sensor Location 0.2 in (5 mm) from tip
Insulation Resistance >1000 MΩ at room temperature
Sheath Material Inconel™
Sheath Dimensions 1760-20: 0.25 in (6.35 mm) (OD) x 20 in (508 mm) (L) 1762-20: 0.25 in (6.35 mm) (OD) x 20 in (508 mm) (L) 0.25 in (6.35 mm) (OD) x 9.75 in (247.65 mm) vertical x 4.5 in (114.3 mm) horizontal
1760-12: 0.25 in (6.35 mm) (OD) x 12 in (305 mm) (L) 1762-12: 0.25 in (6.35 mm) (OD) x 12 in (305 mm) (L)
External Leads Teflon™ insulated copper wire, 4 leads, 6.5 feet (2 meters)  
Handle Dimensions 0.59 in (15 mm) (OD) x 2.56 in (65 mm) (L)
Handle Temperature Range -50°C to 180°C  
[1]  Includes calibration and 100 hour drift.  
[2]  Probe calibration ranges may differ from probe temperature ranges (see Calibrated Accuracy for calibration ranges).  
[3]  Long-term drift rate is for reference only. It could be affected by such facts as handling, application, and maintenance, etc.  
[4]  For 63% response to step change in water moving at 1 meter per second.  

Related Products

Additel AccuMac AM1612 Full Immersion PRT Probe
Price: Call for pricing
Additel AccuMac AM1612 Full Immersion PRT Probe
Temperature Range: -200°C to 160°C Accuracy: <0.05°C Short-term Stability: <0.02°C Transition Junction and Lead Wires Can Withstand the Full Range of the PRT's Widely Used in Climate/Humidity Chambers and Freezers for Validation/Calibration
Additel AccuMac AM1710 Secondary Reference PRT Probe
Price: Call for pricing
Additel AccuMac AM1710 Secondary Reference PRT Probe
Temperature Range: -40°C to 160°C Accuracy: <0.012°C at 0.01°C Long Term Drift: <0.01°C Short-term Stability: <0.007°C Durable and Shock Resistant Temperature Coefficient 0.003925ΩΩ/ Ω/ °C Fully Meets the ITS-90 Criteria for Reference Thermometers
Additel AccuMac AM1751 Secondary Reference PRT
Price: Call for pricing
Additel AccuMac AM1751 Secondary Reference PRT
Affordable Reference Probe Temperature Range: -200°C to 670°C Accuracy: <0.012°C at 0.01°C Short-term Stability: <0.007°C Temperature Coefficient 0.003925 Ω/Ω/°C Fully Meets the ITS-90 Criteria for Reference Thermometers Inconel™ Sheath to Withstand
Additel AccuMac AM1660 and AM1640 Precision Industrial PRTs
Price: Call for pricing
Additel AccuMac AM1660 and AM1640 Precision Industrial PRTs
Temperature Range: -200°C to 670°C Accuracy: <0.035°C Long Term Drift: <0.03°C Short-term Stability: <0.01°C Durable and Shock Resistant Temperature Coefficient 0.00385 Ω/ Ω/ °C Inconel™ Sheath on AM1660/1640 Models
Additel AccuMac AM1730 Secondary Reference PRT Probe
Price: Call for pricing
Additel AccuMac AM1730 Secondary Reference PRT Probe
Affordable Reference Probe Accuracy: <0.012°C at 0.01°C Short-term Stability: <0.007°C Temperature Range: -200°C to 420°C Sheath Diameters Available in 2 Configurations: 1/4 inch and 3/16 inch Inconel™ Sheath to Withstand Harsh Environments Fully Me
Additel AccuMac AM1210 Type S Thermocouple
Price: Call for pricing
Additel AccuMac AM1210 Type S Thermocouple
Affordable Reference Standard Type S Short-term Stability: <0.2°C at 1084.62°C Temperature Range: -196°C to 1300°C