Additel AccuMac AM1612 Full Immersion PRT Probe
|
Manufacturer: ADDITEL *Call for Pricing*
Choose Your Model
Size: |
|
Connection: |
|
|
Additel AccuMac AM1612 Full Immersion PRT Probe
- Temperature Range: -200°C to 160°C
- Accuracy: <0.05°C
- Short-term Stability: <0.02°C
- Transition Junction and Lead Wires Can Withstand the Full Range of the PRT's
- Widely Used in Climate/Humidity Chambers and Freezers for Validation/Calibration
- ISO 17025 Accredited Calibration Included
The AM1612 full immersion PRT is uniquely designed to provide users an excellent temperature probe that can expose the transition junction and the lead wires to an environment that covers the full PRT temperature range. The seal of the probe prevents the ingress of moisture so that the probe can work in humid conditions or even under full immersion in common heat transfer fluid such as ethanol, silicone oil and mineral oil. It has a wide application in freezers, temperature/humidity chambers and sterilizers.
The AM1612 is small in size with a probe length of 1.97 in (50 mm) and diameter of 0.12 in (3 mm). A unique assembly procedure provides the best balance among the hysteresis effect, mechanical shock and thermal shock performance. Each probe comes standard with ISO 17025 Accredited Calibration.
Optional Accessories:
9070- Smart connector for reference PRT for use with Additel temeprature products
9071- Connector adapter from Additel smart connector to 4-wire with gold plated spades
9072- Connector adapter from Additel smart connector to 4-wire with clamps
General Specifications |
|
AM1612-2 |
Temperature Range
|
-200°C to 160°C
|
Nominal Resistance at 0°C
|
100 Ω
|
Temperature Coefficient
|
0.00385 Ω/Ω/°C
|
Accuracy
|
±0.072°C at -200°C
|
±0.05°C at -40°C
|
±0.05°C at 0°C
|
±0.05°C at 160°C
|
Long Term Drift at 0.01°C*
|
<0.04°C at TPW after 100 hours at 160°C
|
Short Term Stability
|
<0.02°C
|
Thermal Shock
|
<0.02°C after 10 thermal cycles from minimum to maximum temperatures
|
Hysteresis
|
≤0.01°C
|
Self-Heating
|
75 mW/°C
|
Response Time**
|
4 seconds
|
Measurement Current
|
1 mA
|
Sensor Length
|
1.18 in (30 mm)
|
Sensor Location
|
0.12 in (3 mm) from tip
|
Insulation Resistance
|
>1000 MΩ at room temperature
|
Sheath Material
|
Stainless Steel
|
Sheath Dimensions
|
0.12 in (3 mm) (OD) x 1.97 in (50 mm) (L)
|
External Leads
|
AM1612-2 = 8.20 feet (2.5 meters)
|
Lead Composition
|
Enameled copper wire protected by high temperature heat shrink tubing, 4 leads
|
* Long-term drift rate is for reference only. It could be affected by such facts as handling, application, and maintenance, etc.
|
** for 63% response to step change in water moving at 1 meter per second
|
|
Temperature Range: -40°C to 160°C
Accuracy: <0.012°C at 0.01°C
Long Term Drift: <0.01°C
Short-term Stability: <0.007°C
Durable and Shock Resistant
Temperature Coefficient 0.003925ΩΩ/ Ω/ °C
Fully Meets the ITS-90 Criteria for Reference Thermometers
|
Affordable Reference Probe
Temperature Range: -200°C to 670°C
Accuracy: <0.012°C at 0.01°C
Short-term Stability: <0.007°C
Temperature Coefficient 0.003925 Ω/Ω/°C
Fully Meets the ITS-90 Criteria for Reference Thermometers
Inconel™ Sheath to Withstand
|
Temperature Range: -200°C to 670°C
Accuracy: <0.035°C
Long Term Drift: <0.03°C
Short-term Stability: <0.01°C
Durable and Shock Resistant
Temperature Coefficient 0.00385 Ω/ Ω/ °C
Inconel™ Sheath on AM1660/1640 Models
|
Affordable Reference Probe
Accuracy: <0.012°C at 0.01°C
Short-term Stability: <0.007°C
Temperature Range: -200°C to 420°C
Sheath Diameters Available in 2 Configurations: 1/4 inch and 3/16 inch
Inconel™ Sheath to Withstand Harsh Environments
Fully Me
|
Reliable SPRT for Daily Use
Rtpw Drift: <4mK after 100hrs at 661°C
Short-term Stability : <0.002°C at 0.01°C
Temperature Range: -200°C to 670°C
Inconel™ Sheath to Withstand Harsh Environments
Fully Meets the ITS-90 Criteria for Reference Thermometers
|
Affordable Reference Standard
Type S
Short-term Stability: <0.2°C at 1084.62°C
Temperature Range: -196°C to 1300°C
|
• Temperature control from 100°C to 1210°C
• Two models to choose from: Reference (ADT878) and Standard (ADT875)
• Display Accuracy of ±1.5°C (ADT878)
• 4 on-board measurement channels (PC option)
|
• Three models ranging from -40℃ to 700℃
• Reference level performance in accuracy, stability & uniformity
• Quick to temperature
• Two-channel readout measures RTDs and TCs, & provides task documentation
• Full HART communicator
• Wi-Fi & Bluetooth
|
Additel’s 282 delivers the best possible accuracies and features in the palm of your hand! With accuracy capabilities on par with laboratory grade thermometers, the ADT282 is capable of handling even your most critical measurement.
|
|
|