Laureate Thermocouple Temperature Panel Meter / Controller

<< Previous in Indicators Next in Indicators >>

Price: $230.00
Item Is In Stock
Configuration: L10000JC
Manufacturer: LAUREL

Options

* denotes required field

Main Board*
Power*
Relay Output*
Analog Output*
Serial Communications*
Signal Input*
Optional Add-Ons

Laureate Thermocouple Temperature Panel Meter / Controller
High accuracy plus linearized transmitter & control outputs


Features

-Factory calibrated for thermocouple types J, K, T, E, N, R, S
-Entire range of each thermocouple in one scale
-Selectable 1° or 0.°1, degrees Celsius, Fahrenheit, Kelvin or Rankin
-Up to 60 conversions per second, peak or valley display
-Universal 85-264 Vac power, or 10-48 Vdc / 12-32 Vac power
-Wide choice of options:
  -2 or 4 relays, mechanical or solid state (isolated)
  -Analog output, 4-20 mA, 0-10V, or -10V to +10V (isolated)
  -Serial data I/O: Ethernet, USB, RS485, RS232 (isolated)
  -Custom curve linearization, rate from consecutive readings


Options

Serial communications: Ethernet Interface, Ethernet-to-RS485 server, USB Interface, USB-to-RS485 server, RS485 interface (dual RF11), RS485 Modbus interface (dual RJ45), RS232 interface.
Low voltage power: 10-48 Vdc or 12-32 Vac
Relay outputs: 2 or 4 relays, contact or solid state
Analog output: isolated 4-20 mA, 0-20 mA, 0-10V, 10 to +10V


Description

The Laureate thermocouple meter is factory calibrated for type J, K, T, E, N, R and S thermocouples for exceptional accuracy and repeatability. The entire span of each thermocouple type is presented in a single range. The thermocouple type, unit of measure (°C or °F), resolution (1° or 0.1°), and upscale or downscale open sensor indication are selectable from the front panel or via the serial interface. Display in Kelvin or Rankin is selected by offsetting the Celsius or Fahrenheit ranges. Cold junction compensation is standard.

All ranges for all temperature sensor types are digitally calibrated at the factory, with calibration factors stored in an EEPROM on the signal conditioner board. This allows temperatures sensors and signal conditioner boards to be changed in the field without recalibrating the meter.

High read rates at up to 60 or 50 conversions per second while integrating the signal over a full power cycle are provided by Concurrent Slope (US Pat 5,262,780) analog-to-digital conversion. High read rates are ideal for peak or valley capture, real-time computer interface, and control. Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or a control signal at the rear connector, or be transmitted as serial data.

Digital filtering is selectable for electrically noisy environments, including a batch averaging filter and an adaptive moving average filter which provides a choice of 8 time constants from 80 ms to 9.6 s. When a significant change in signal level occurs, that filter adapts by briefly switching to the shortest time to follow the change, then reverts back to the selected time constant. In a selectable Auto filter mode, the filter time constant is automatically selected based on detected signal noise.

Designed for system use. Optional plug-in boards for communications and control include Ethernet and other serial communication boards, dual or quad relay boards, and an isolated analog output board. Laureates may be powered from 85-264 Vac Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.


View the Data/Spec Sheet

View the Manual