Kanomax Indoor Air Quality Monitor IQM 60
|
|
Item Is In Stock
|
| The complete
instrument for performing in-depth analysis of indoor air quality.
|
|
|
|
The IQM 60 Indoor Air
Quality Monitor enables simultaneous
monitoring of the most common parameters for indoor air quality with a
single instrument. Parameters measured include gases such as CO2, CO,
VOC, NO2, O3 plus temperature, humidity and respirable particulates.
Data
is logged to a removable SD card or remote PC using supplied software
and can be exported to MS Excel for generating reports. Utilizing high
performance Analytic GSS Technology and other optical sensors, the IQM
60 offers the complete package for performing in-depth analysis and
long term studies of indoor air quality.
|
|
|
|
|
| Applications
|
Features
|
- IAQ Complaint Investigation and Analysis
- HVAC System Performance Monitoring
- Sick Building Syndrome (SBS)
- Health and Comfort Assessment
- Mould Investigation and Remediation
- Airport Lounges
- Office Buildings
- Shopping Malls
- Schools and Kindergartens
- Hospitals
- Elderly Care Facilities
|
- Analytic
GSS Technology / PID / NDIR
- Multiple
Gas Sensors (up to six)
- Factory
Certified with NIST Traceability
- Temperature
and Humidity Sensors
- Particulate
Monitor (optional)
- Active
Air Sampling System
- Rapid
Real-time Data Sampling
- Min
/ Max / Average Sampling
- Large
Internal Data Storage Capacity
- RS
232 / USB Communication
- PC
Data Logging Software
- User
Defined Calibration
- Wireless
Communication (optional)
- Quiet
Operation
- Low
Maintenance
-
Portable
|
|
|
Specifications
|
|
|
Interface
|
RS232
(Serial cable and USB adapter supplied)
|
Data
Storage
|
Removable
SD card 1GB
|
Wireless
Communication
(option)
|
GSM modem
|
Power
Supply
|
AC adapter
/ External Li-ion portable power station (optional)
|
Enclosure
|
Aluminium
and powder coated steel
|
Dimensions
|
W 10.9 x D
9.3 x H 5.2 inches (278 x 236 x 132 mm)
|
Weight
|
Approx. 11
lb (5.0 kg)
|
Standard
Accessories
|
Operation
Manual, Standard Sensors (CO, CO2, Temperature, R/H),
AC Adapter, PC Configuration and Data Logging Software
|
Optional Accessories
|
TSP
Particulate Monitor, PM2.5 Cyclone, PM10 Cyclone, Replacement PID Lamp
|
Optional
Sensor Module
|
- VOC
isobutylene sensor module
- PID
isobutylene sensor module
- Ozone
sensor module
- Nitrogen
dioxide sensor module
- Non Methane
Hydrocarbon sensor module
- Hydrogen
sulphide sensor module
- Ammonia
sensor module
|
|
|
|
Gas Sensor Modules
|
Gas Sensor Modules
|
Sensor
|
Range
(ppm)
|
Lowest
detection
|
Accuracy
|
Precision
|
Resolution
|
Carbon
dioxide
|
NDIR
|
0
- 2,000
|
6
ppm
|
<40
ppm + 3%
|
6
ppm
|
1
ppm
|
Carbon
dioxide
|
NDIR
|
0
- 5000
|
6
ppm
|
<150
ppm + 5%
|
6
ppm
|
1
ppm
|
Carbon
monoxide
|
GSS
|
0
- 100
|
0.5
ppm
|
<+/-
5 ppm
|
1
ppm
|
0.1
ppm
|
VOC
isobutylene
|
GSS
|
0
- 25
|
0.1
ppm
|
<+/-
10%
|
0.2
ppm
|
0.1
ppm
|
VOC
isobutylene
|
PID
|
0
- 20
|
10
ppb
|
<10%
|
0.02
ppm
|
0.01
ppm
|
Non-methane
hydrocarbon
|
GSS
|
0
- 25
|
0.1
ppm
|
<+/-
0.5 ppm
|
0.2
ppm
|
0.1
ppm
|
Hydrogen
sulphide
|
GSS
|
0
- 10
|
10
ppb
|
<+/-
0.5 ppm
|
0.02
ppm
|
0.01
ppm
|
Nitrogen
dioxide
|
GSS
|
0
- 0.200
|
10
ppb
|
<+/-
15%
|
0.005
ppm
|
0.001
ppm
|
Ozone
|
GSS
|
0
- 0.150
|
1
ppb
|
<+/-
0.005 ppm
|
0.002
ppm
|
0.001
ppm
|
Ozone
|
GSS
|
0
- 0.500
|
1
ppb
|
<+/-
0.008 ppm
|
0.004
ppm
|
0.001
ppm
|
* Other parameters available
|
|
Temperature / Humidity
Sensor
|
Sensor
|
Range
|
Accuracy
|
Resolution
|
Temperature
|
-20
- 100C
|
+/-
0.3C @ 25C
|
0.1C
|
Humidity
|
0
- 100%RH
|
+/-
2%RH @ 25C
|
0.1%RH
|
|
| Particle Monitor
|
| Range
|
Particle
Size
|
Precision
|
Accuracy
|
LT
Stabolity
|
Cut
Points
|
1
- 2000μg/m
|
0.1
- 100μm
|
3μg/m
|
8%
NIOSH 0600
|
5%
of reading
|
TSP,
PM1, PM2.5, PM10
|
|
|
|
|