Crystal XP2I Digital Test Gauge
|
|
Price: From $940.00 to $1,195.00
Deliver in 14 days
Manufacturer: CRYSTAL ENGINEERING
Choose Your Model
| |
| |
| |
|
Overview
Ultra rugged, intrinsically safe, digital test gauge with 0.1% of reading accuracy.
- Marine grade enclosure resists corrosion
- Accuracy not affected from -10 to 50°C
- Replaces 5 or more digital test gauges
- Fast pressure safety valve (PSV) mode
- Define custom pressure units
- Shift everyday wear to replaceable CPF adapter
- Easy to use-No Menu. No Manual? No Problem!
With the optional DataLoggerXP upgrade:
- Record 32 000 data points
- Battery-optimizing, Ultra Low Power (ULP) Mode
- Over an entire year of continuous recording time
- Now available on the Dual-Line Display XP2i
Applications
- Field gauge calibration
- Permanent outdoor installation
- Burst disc testing
- Pressure safety valve (PSV) testing
- Hydraulic torque wrench indication
- Torque datalogging
- Pressure regulator testing
- Pipeline static pressure testing
- Chart recorder replacement
- Wellhead monitoring
- Filter performance testing
- Hydrostatic leak testing
Specifications

| 0 to 20% of Range: |
± (0.02% of Full Scale) |
Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. |
| 20% to 110% of Range: |
± (0.1% of Reading) |
All models indicate vacuum, but vacuum specification applies to 15 PSI, 30 PSI, 100PSI, and 300PSI models only. |
| Vacuum: |
± (0.25% of Full Scale*) |
Not recommended for continuous use below -14.5 PSI. |
| |
* Full Scale = -14.5 PSIG |
Refer to XP2i-DP data sheet for gauges that are intended for continuous high vacuum use. |

| Temperature Range: |
-10 to 50°C (14 to 122°F) |
Non-condensing. No change in accuracy over operating temperature range. Gauge must be zeroed to achieve rated specification. |

| Screen: |
5.5 digits 16.9 mm (0.67") high |
LCD readable in sunlight with bright backlight. |
| Display Rate: |
4 rdgs/sec (standard) |
|
| |
8 rdgs/sec (PSV Mode) |
PSV mode is intended for Pressure Safety Valve testing, and requires software to enable. |

| 3 x AA: |
1500 hours, typical |
Uses 3 alkaline AA (LR6) batteries. Use of backlight and/or RS232 reduces operating time. |
| |
|
Optional AC power supply available. Do not use AC power supply in hazardous locations. |
| Ultra Low Power: |
Over 1 year, typical** |
** 20 minute recording interval or greater in LT5 mode. |

| Digital Interface: |
RS232, DB-9F |
Free Labview drivers and programming instructions are available for download from website. |
| |
|
Do not use RS32 in hazardous locations. |

| Capacity: |
32 000 data points |
DataLoggerXP Firmware Update may be purchased at time of order, or in an Upgrade Package later. |
| Storage Type: |
Flash memory |
Software available for download from our website. |
| Minimum Interval: |
1 second |
Compatible w/ 32 & 64 bit Windows 7, Vista, and XP 32 bit. |
| Maximum Interval: |
18 hours |
Produces csv files, or used Excel template files (samples included) to automatically format and graph data. |
| Min. Event Duration: |
250 mS*** |
*** Logging Type - Average with Peaks. |

| Weight: |
562 g (19.8 oz) |
Weight includes batteries. |
| Rating: |
IP67 |
Submersible to 1 m for 30 minutes [IEC 60529]. |
| Housing: |
Diecast aluminum |
Nickel plating over low copper, marine grade aluminum. |
| Keypad and Labels: |
UV Resistant Polyester |
LCD protected from impact damage by 1.5 mm (0.06") thick polycarbonate lens under polyester window. |
| |
|
Skydrol compatible. |

| Wetted Materials: |
316 stainless steel |
All welded, with a permanently filled diaphragm seal. |
| |
and Viton internal o-ring (finger tight) |
Metal to metal cone seal; O-ring can be removed if necessary. |
| Diaphragm Seal Fluid: |
Dow Corning 200 |
Optional connection on back. |
| Connection: |
Crystal CPF Female |
1/4" male NPT adapter included unless BSP or M20 is specified. |
| |
|
1/4" medium pressure tube system compatible with HiP LM4 and LF4 Series, Autoclave Engr SF250CX Male and Female Series. |

| Temperature Range: |
-40 to 75°C (-40 to 167°F) |
Batteries should be removed if stored for more than one month. |

The following requires the use of our free ConfigXP software.
| User Defined Unit: |
Allows the user to define and display any pressure units not included, or to use the gauge to display force, level, or other pressure related parameters. Reduce or increase displayed resolution. |
| PSV Mode: |
Intended for pressure safety valve / burst disk testing. 8 readings per second. Captures point at which valve opens, as well as reseat pressure. |
| Averaging: |
Smooths unsteady readings (1 to 10 samples). |
| Remove: |
Unwanted pressure units from Units button. |
| Disable: |
Peak pressure button. |
| Limit or Disable: |
Zero button. |
| Password Protect: |
Changes to configuration or calibration factor(s). |
| Save: |
Configuration to a file. |
| Copy: |
Configuration to other gauges. |

 |
II 1 G Ex ia IIC T4/T3 Ga FTZU 12 ATEX 0048X |
| |
This product conforms to: EN 60079-0:2009 | EN 60079-11:2012 | EN 60079-26:2007 |
 |
Ex ia IIC T4/T3 Ga IECEx FTZU 12.0009X |
| |
This product conforms to: IEC 60079-0:2011 | IEC 60079-11:2011-06 | IEC 60079-26:2006 |
 |
XP2i complies with the Electromagnetic Compatibility and the Pressure Equipment Directives. Refer to the EC Declaration of Conformity for specific details. |
 |
The instrument was tested against AS/NZS 3584, C-tick EMC/EMI requirements. |
 |
XP2i is approved for use a portable test instrument for Marine use and complies with Det Norsjke Veritas' Rules for Classification of Ships, High Speed & Light Craft and Offshore Standards. |

| PSI |
bar |
kPa |
MPa |
|
Display Resolution |
| P/N |
P/N |
P/N |
P/N |
Over pressure |
PSI |
inH2O |
inHg |
mmHg |
mmH2O |
kg/cm2 |
bar |
mbar |
kPa |
MPa |
| 15PSI |
1BAR |
100KPA |
0.1MPA |
6.5x |
0.001 |
0.01 |
0.001 |
0.01 |
1 |
0.0001 |
0.0001 |
0.1 |
0.01 |
0.00001 |
| 30PSI |
2BAR |
200KPA |
0.2MPA |
3.0x |
0.001 |
0.01 |
0.001 |
0.1 |
1 |
0.0001 |
0.0001 |
0.1 |
0.01 |
0.00001 |
| 100PSI |
7BAR |
700KPA |
0.7MPA |
2.0x |
0.01 |
0.1 |
0.01 |
0.1 |
1 |
0.0001 |
0.0001 |
0.1 |
0.01 |
0.00001 |
| 300PSI |
20BAR |
2KKPA |
2MPA |
2.0x |
0.01 |
0.1 |
0.01 |
1 |
|
0.001 |
0.001 |
1 |
0.1 |
0.0001 |
| 500PSI |
30BAR |
3KKPA |
3MPA |
2.0x |
0.01 |
1 |
0.1 |
1 |
|
0.001 |
0.001 |
1 |
0.1 |
0.0001 |
| 1KPSI |
70BAR |
7KKPA |
7MPA |
2.0x |
0.1 |
|
0.1 |
|
|
0.001 |
0.001 |
|
0.1 |
0.0001 |
| 2KPSI |
140BAR |
14KKPA |
14MPA |
2.0x |
0.1 |
|
0.1 |
|
|
0.01 |
0.01 |
|
1 |
0.001 |
| 3KPSI |
200BAR |
20KKPA |
20MPA |
1.5x |
0.1 |
|
0.1 |
|
|
0.01 |
0.01 |
|
1 |
0.001 |
| 5KPSI |
300BAR |
30KKPA |
30MPA |
1.5x |
0.1 |
|
1 |
|
|
0.01 |
0.01 |
|
1 |
0.001 |
| 10KPSI |
700BAR |
70KKPA |
70MPA |
1.5x |
1 |
|
|
|
|
0.01 |
0.01 |
|
1 |
0.001 |
Unneeded pressure units may be disabled via the RS-232 connector using ConFigXP software. • kPa and MPa models can display pressure in kPa, MPa, and bar (or mbar) only. PSI and bar models can display all available units. • An XP2i will indicate pressure up to 10% above Range Pressure. Above 110%, the XP2i display will flash, indicating that the applied pressure exceeds the calibrated pressure range. If the calibrated pressure range is exceeded, the pressure displayed may not be accurate. • An Absolute version is available for XP2i gauges with ranges of 2000 PSI and higher.
|
Software to customize your Crystal XP2i digital pressure gauge. Add or delete units of measure, upload firmware changes, and more!
Compatible with Windows 2000, XP and VISTA
| | |
|
|