Your cart is empty.



   
 

   

 

Additel ADT 761 Automated Pressure Calibrator

<< Previous in Field Calibrators Next in Field Calibrators >>

Price: From $10,800.00 to $13,800.00
Manufacturer: ADDITEL

Choose Your Model

Options

* denotes required field

Optional Accessories
Certification Options*

Additel ADT 761 Automated Pressure Calibrator

Fully automated, portable pressure calibrator with built-in pressure generator / controller, up to 375 psi (25 bar)

Accessories(Included):
ADT106-N, ADT106-B or ADT106-M External Pressure Manifold 1 pc
9818 110V/220V external Power adapter 1 pc
9722 Chargeable Li-ion battery 1 pc
9022 Test Leads for calibrator 2 sets(4 pc)
9020 Short circuit cable 1 set(2 pc)
9907 Carrying case for ADT761 calibrator and accessory 1 pc
O-rings 20
Manual 1 pc
Tools 1 sets
Hose 2 pc
NIST Traceable Calibration Certificate 1 pc


Overview

The Additel ADT 761 automated pressure calibrator with a built-in high performance electronic pump and precision pressure controller provides a turn-key solution for calibration of gauges, transmitters, and switches both in the field and in the laboratory. In a portable package, this little calibrator can automatically generate from 90% vacuum to 375 psi (25 bar) pressure with 0.005%FS pressure control stability and 0.02%FS accuracy. To improve the calibrator accuracy, two pressure modules with differing ranges are used. These are built-in and integrated with the internal pump and controller. With optional external pressure modules (ADT160 series), the ADT761 can measure pressures up to 10,000 psi (700 bar) with 0.025%FS accuracy. In addition to the pressure generation, control, and measurement capabilities, the ADT761 also features HART communication capability, supply 24V loop power, and read the current or voltage produced by the pressure transducers. The state of art ADT761 automated pressure calibrator brings automated pressure calibration to the field.

FEATURES

• Pressure Range
Pressure generated by built-in pump and controlled automatically from 90% vacuum to 375 psi (25 bar)
Pressure measured with external pressure modules (ADT160 series) to 10,000 psi (700 bar)
• Accuracy 
0.02%FS 
Fully temperature compensated
• Control Stability 
0.005%FS
• Automation and Test Program 
Fully Automated pressure calibration 
Task preset and auto run 
Auto step
• Easy to Use 
User friendly interface 
Intuitive icon driven menu structure
• Sourcing and Measuring electrical signals 
Measure mA or V with 0.01% RD + 0.005%FS accuracy 
Source 0 to 22mA current 
24 VDC loop power supply to pressure transmitter during test 
Automatic switch test
• Misuse Protection 
Up to 30V misuse protection on any two sockets
• Display 
7" LCD color screen (800X480)
• Documenting and data logging 
Task management capability 
Internal memory stores 120 tasks 
Download tasks and upload results
• Hart Communication capability 
Support HART instrumentation
• Rechargeable battery 
Rechargeable battery with up to 8 hours operation between charges
Leak testing 
Apply leak test to an external pressure system to determine the magnitude of pressure variations due to leaks
Pipeline Protection 
Special design the pipeline layout to avoid possible blockage and leakage
• Portable 
Only 12 lb
• Multi Lingual Interface 
English, Chinese
• NIST Traceable 
NIST traceable calibration certificate included


SPECIFICATIONS
• Pressure Ranges
Model Pressure Range
Pressure Module 1
Range
Pressure Module 1
Accuracy
Pressure Module 2
Range
Pressure Module 2
Accuracy
ADT761-D -0.95 to 1 bar
(-14 to 15 psi)
-25 to 25 mbar
(-10 to 10 in
H2O)
0.05%FS -1 to 1 bar
(-15 to 15 psi)
0.02%FS
ADT761-L -0.95 to 7 bar
(-14 to 100 psi)
-1 to 2.5 bar
(-15 to 35 psi)
0.02%FS 0 to 7 bar
(0 to 100 psi)
0.02%FS
ADT761-M -0.90 to 25 bar
(-13 to 375 psi)
-1 to 2.5 bar
(-15 to 35 psi)
0.02%FS 0 to 25 bar
(0 to 375 psi)
0.02%FS
* ADT761 calibrators support ADT160 series intelligent digital pressure modules that are available for gauge, vacuum and absolute pressure from -15 psi to 10,000 psi (-1 bar to 700 bar). Accuracy from 0.025%FS includes operation over 14°F to 122°F (-10°C to 50°C), one year stability and calibration uncertainty. For detailed specification refer to ADT160 series pressure modules datasheet. 
• Electrical Measurement and Source Accuracy 
Range Resolution Accuracy
Voltage Measurement   ±30.0000V 0.1mV ±(0.01%RD + 0.005%FS)
Current Measurement    ±30.0000mA 0.1uA  ±(0.01%RD + 0.005%FS)
Current Source 0.000 to 22.000mA 1uA ±(0.02%RD + 0.01%FS)

On-off Measurement   If the switch has detective Voltage, the range is from 3V to 24V 
DC 24V output 24V ± 0.5V

• Control Stability 
<0.005%FS
• Pressure Connections 
0.156 inch (Φ4 mm) test hose on calibrator 
Two 1/4"NPT female hand-tight connectors on the external pressure manifold (included)
• External Pressure Module Connection 
External pressure module connector
• Electrical Connection 
0.156 inch (4mm) banana sockets
• Data Logger 
Storage capacity: 120 files maximum
• Display 
7"LCD color screen (800X400) 
Display rate: 5 readings per second
• Pressure Units 
Pa, kPa, MPa, psi, bar, mbar, inH2O@4°C, mmH2O@4°C, inHg@0°C, mmHg @0°C, kgf/cm2
• Power 
Battery: Rechargeable Li-ion Polymer battery (included) 
Li-Battery working time: ~8 hours 
Recharge time: ~3 hours 
External Power: 110/220V Power adapter (DC 27 V) (Included)
• Environmental Specification 
Operating temperature: 0°C to 50°C 
Storage temperature: -20°C to 60°C 
Humidity: <90%, non-condensing
• European Compliance 
CE Marked
• Communication 
RS232 (DB9/F, environmentally sealed) 
Baud rate: 2400, 4800, 9600, 19200, 38400, 57600, 115200 
Data length: 7 Bits, 8 Bits 
Stop bit: 1 Bit, 2 Bits 
Address: from 1 to 121
• Dimension 
11.65" X 7.32" X 7.09" (296mm X186mm X180mm)
• Weight 
12.4 lb (5.6 kg)
• Warranty 
18 months


View the Data/Spec Sheet. Don't have Reader?
View the Manual.  

 | Additel Land Software